1. Hormone feedback pathway

Hypothalamus releases TRH, pituitary releases TSH, thyroid releases T4 and T3; thyroid hormones feed back to the brainHypothalamusTRHAnterior pituitaryTSH-producing cellsTSHThyroid glandT4 and T3Negative feedback −−−

The hypothalamus releases thyrotropin-releasing hormone (TRH), which stimulates TSH secretion by anterior pituitary thyrotrophs.

2. Build a sandwich immunoassay

Schematic sandwich assay: capture antibody on a solid phase binds TSH, then a labelled detection antibody binds another epitope, generating a measurable signalSolid phaseTSHLabelSignal
Capture antibodyTSHDetection antibody

A capture antibody is attached to a solid phase such as a magnetic microparticle. It recognises an epitope on TSH.

Schematic only: not to molecular scale or a manufacturer-specific reaction sequence. Separation and washing depend on assay design. Within the validated measuring range, signal generally increases with TSH concentration.

3. Explore thyroid function patterns

These are teaching examples, not a diagnostic calculator. “Raised” and “low” mean relative to the appropriate laboratory reference interval.

TSH↑ Raised
FT4↓ Low
FT3Variable

Raised TSH with low FT4 is compatible with overt primary hypothyroidism. Reduced thyroid hormone availability removes negative feedback, so an intact pituitary increases TSH.

Interpret results with clinical findings, medicines, pregnancy status and assay limitations. Mixed or discordant patterns require clinical–laboratory discussion; they do not establish a diagnosis by themselves.

Test at a glance

ParameterInformation
AnalyteThyroid-stimulating hormone (thyrotropin)
SpecimenSerum or method-validated plasma
UnitsmIU/L
Reference intervalUse the reporting laboratory’s age-, population- and method-appropriate interval
MethodQuantitative two-site immunoassay
Clinical roleInvestigation and monitoring of thyroid dysfunction

Physiology

TSH is a heterodimeric glycoprotein secreted by anterior pituitary thyrotrophs in response to hypothalamic thyrotropin-releasing hormone (TRH). It activates the TSH receptor on thyroid follicular cells, stimulating iodide uptake, thyroglobulin metabolism and thyroid hormone synthesis and secretion. T4 and T3 exert negative feedback at the hypothalamus and pituitary. TSH secretion is pulsatile and circadian.

Investigate suspected primary thyroid dysfunction, monitor primary hypothyroidism during replacement therapy and assess thyroid status following treatment. TSH alone is insufficient where central thyroid dysfunction is suspected. FT4 and FT3 help characterise abnormal TSH; thyroid peroxidase antibodies (TPOAb) support investigation of autoimmune thyroiditis and TSH receptor antibodies (TRAb) help identify Graves’ disease.

Specimen and pre-analytical considerations

ParameterGeneral requirement
CollectionVenous blood in a compatible serum or plasma collection tube
AnticoagulantOnly types verified for the assay
FastingUsually unnecessary for TSH alone
PreparationAllow serum to clot; centrifuge appropriately; avoid residual fibrin and cells
Transport and storageFollow validated time and temperature conditions for the method
RejectionIncorrect identification, unsuitable specimen type, compromised integrity or insufficient volume under local criteria
Clinical informationMedication, supplements, pregnancy, acute illness and previous thyroid results

Analytical methodology

Most TSH assays use a capture antibody and labelled detection antibody recognising distinct epitopes. Solid-phase separation removes unbound components in heterogeneous methods. Chemiluminescent, electrochemiluminescent and enzyme-linked detection systems are widely used. A calibration curve relates the measured signal to TSH concentration. The signal generally increases with concentration within the validated range.

Analytical measuring interval, limit of blank, detection and quantitation, dilution suitability, precision and bias are method-dependent. Laboratories verify these characteristics before clinical use. Results below a validated quantitation limit should not be reported as zero.

Clinical interpretation

TSHFT4FT3Possible interpretation
HighLowVariablePrimary hypothyroidism
HighNormalUsually normalSubclinical hypothyroidism
LowHighHigh or normalPrimary thyrotoxicosis
LowNormalHighT3 thyrotoxicosis
LowNormalNormalPossible subclinical hyperthyroidism
Low or inappropriately normalLowVariableCentral hypothyroidism or non-thyroidal illness
Non-suppressedHighVariableDiscordant results requiring investigation

In adults with suspected primary thyroid dysfunction, TSH-first testing can be followed by FT4 when high and FT4 plus FT3 when low. Initial TSH and FT4 testing is appropriate when pituitary disease is suspected or in children and young people. Pregnancy and neonatal testing require separate interpretation pathways. Clinical decision thresholds are not equivalent to reference intervals.

Analytical interferences and specimen limitations

FactorPotential consequence
Heterophile or anti-animal antibodiesFalsely high or low measurement
Macro-TSHPersistent apparent elevation of TSH
BiotinFalsely low TSH in susceptible sandwich assays; effects depend on architecture
High-dose hook effectPotential falsely low result in susceptible methods at extreme analyte concentrations
Fibrin, haemolysis, lipaemia or icterusEffects depend on specimen and method

Unexpected patterns may require review of clinical history, repeat or alternative-platform measurement, validated dilution, heterophile blocking or polyethylene glycol precipitation. Interpret investigations in conjunction with specialist laboratory advice.

Acute illness, pregnancy, circadian rhythm and medicines such as glucocorticoids or dopamine can alter TSH physiology. These biological influences are distinct from analytical interference. Human chorionic gonadotrophin (hCG) affects thyroid physiology in pregnancy. Use appropriate clinical and laboratory interpretation.

Quality assurance and reporting

Review calibration, reagent status, internal quality control (IQC), analyser flags, specimen suitability and relevant prior results. Participate in external quality assessment (EQA) and review performance over time. Resolve unacceptable QC before releasing affected results. Apply laboratory-specific escalation, reporting and repeat-testing policies. Monitor changes in method and reagent lots for clinically significant bias.

Related learning

References and further reading

Sources checked 28 November 2026.

;